Termite collars at the slab in Melton South
Fitted once, before the pour, or never at all.
In short: The collar around each slab penetration is the one termite defence that cannot be retrofitted.
What a collar does
It seals the gap where a pipe passes through the slab, closing a route termites would otherwise use undetected.
Why timing is absolute
The penetration is cast into concrete. Once poured, there is no way back to it.
What we have found
Collars missing from all or some plumbing penetrations at Melton South pours.
How to check
Ask to see them before the pour, or book the slab inspection and have it recorded.
What else sits at slab
Vapour barrier position, mesh support, cover and N16 bars around penetrations.
Written by the Owner Inspections team from inspections carried out in Melton South. Licensed building practitioners, Building & Plumbing Commission registration CDB-U 53425.